Error Code

Message Information

HWC4000

Message

A hardware incompatibility detected between BMC/iDRAC firmware
and CPU.

LCD Message

Incompatibility between BMC/iDRAC firmware and CPU. Update
firmware.

Details

A hardware incompatibility was detected between BMC/iDRAC
firmware and Processor(s). An iDRAC or BMC firmware update is
needed.

Action

Update the BMC/iDRAC firmware. If the issue persists, see

Getting

Help

.

HWC4002

Message

A hardware incompatibility detected between BMC/iDRAC firmware
and other hardware.

Details

A hardware incompatibility was detected between BMC/iDRAC
firmware and other hardware. An iDRAC or BMC firmware update is
needed.

Action

Update the BMC/iDRAC firmware. If the issue persists, see

Getting

Help

.

HWC4011

Message

Hardware unsuccessfully updated for PCIe mezzanine card
<

number

>.

Action

Check presence of the hardware, reinstall or reconnect, then
reattempt the update. If the issue persists, see

Getting Help

.

HWC4013

Message

Hardware unsuccessfully updated for embedded NIC.

Action

Check presence, reinstall or reconnect, then reattempt the update. If
the issue persists, see

Getting Help

.

HWC4015

Message

Link Tuning error detected.

Details

CMC has old firmware. After updating the firmware the CMC will
recognize the device.

Action

Update the CMC firmware. If the issue persists, see

Getting Help

.

HWC5001

Message

<

name

> is offline.

Action

If unexpected, check presence, then reinstall or reconnect.

HWC5002

Message

A fabric mismatch detected on <

name

>.

Details

The fabric type for the IOM and PCIe mezzanine cards must match.

92