Dell PowerEdge VRTX User Manual

Page 116

Advertising
background image

Error Code

Message Information

RFM1006

Message

Removable Flash Media <

name

> is offline.

Details

At boot, the Card Identification (CID) signature of the card is different
from the Non-volatile (NV) storage value or the card is the destination
of a copy operation that is in-progress.

Action

If unintended, reinstall the flash media.

RFM1008

Message

Failure detected on Removable Flash Media <

name

>.

LCD Message

Removable Flash Media <

name

> failed. Check SD Card.

Details

An error was reported during a SD card read or write.

Action

Reseat the flash media, if the issue persists replace the media.

RFM1014

Message

Removable Flash Media <

name

> is write protected.

LCD Message

Removable Flash Media <

name

> is write protected. Check SD Card.

Details

The card is write-protected by the physical latch on the SD card. A
write-protected card cannot be used.

Action

If unintended, remove the media and disable write protection.

RFM1016

Message

Media not present for Removable Flash Media <

name

>.

Details

The SD card is not detected or not installed.

Action

If unintended, reinstall the flash media.

RFM1021

Message

Removable Flash Media is not IPMI-function ready.

Details

The removable flash media is installed but improperly configured or
failed to initialize.

Action

If unintended, reinstall the flash media.

RFM1022

Message

Removable Flash Media is ready.

Action

If unintended, reinstall the flash media.

RFM1023

Message

Removable Flash Media is not ready.

Details

The media is being prepared or is under maintenance. If the problem
persists, reinstall the card.

Action

If unintended, reinstall the flash media.

116