Dell PowerEdge VRTX User Manual

Page 120

Advertising
background image

Error Code

Message Information

SEC0033

Message

The chassis is open while the power is off.

LCD Message

Intrusion detected. Check chassis cover.

Details

The chassis was opened while the power was off. System security
may have been comprised.

Action

Close the chassis and verify hardware inventory. Check system logs.

SEC0040

Message

A critical stop occurred during OS load.

Details

Operating system generated critical stop IPMI event. (Sensor type
code = 20H)

Action

Check video and operating system logs for additional information

SEC0041

Message

BIOS detected an error configuring the Intel Trusted Execution
Technology (TXT).

LCD Message

BIOS detected an error configuring TXT. Check system configuration.

Details

TXT initialization failure. System configuration may have changed.

Action

Check system hardware inventory and software configuration.

SEC0042

Message

Processor detected an error while performing an Intel Trusted
Execution Technology (TXT) operation.

LCD Message

CPU detected an error while performing a TXT operation. Check
system configuration.

Details

TXT CPU microcode boot failure. System configuration may have
changed.

Action

Check system hardware inventory and software configuration.

SEC0043

Message

BIOS Authenticated Code Module detected an Intel Trusted
Execution Technology (TXT) error during POST.

LCD Message

BIOS detected a TXT error during POST. Check system configuration.

Details

TXT Post failure. System configuration may have changed.

Action

Check system hardware inventory and software configuration.

SEC0044

Message

SINIT Authenticated Code Module detected an Intel Trusted
Execution Technology (TXT) error at boot.

LCD Message

SINIT detected a TXT error at boot. Check system configuration.

Details

TXT initialization failure. System configuration may have changed.

120