Troubleshooting An Internal SD Card

CAUTION: Many repairs may only be done by a certified service technician. You should only perform
troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or
telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your
warranty. Read and follow the safety instructions that came with the product.

1.

Enter the System Setup and ensure that the Internal SD Card Port is enabled.

2.

Note the Internal SD Card Redundancy option enabled in the Integrated Devices screen of the System Setup

(Mirror or Disabled).

3.

Remove the server module from the enclosure.

4.

If the Internal SD Card Redundancy option in the Integrated Devices screen of the System Setup is set to Mirror

mode and SD card 1 has failed:
a) Remove the SD card from SD card slot 1.
b) Remove the SD card present in SD card slot 2 and insert it into SD card slot 1.
c) Install a new SD card in slot 2.

5.

If the Internal SD Card Redundancy option in the Integrated Devices screen of the System Setup is set to Mirror

mode and SD card 2 has failed, insert the new SD card into SD card slot 2.

6.

If the Internal SD Card Redundancy option in Integrated Devices screen of the System Setup is set to Disabled,

replace the failed SD card with a new SD card.

7.

Install the server module in the enclosure.

8.

Enter the System Setup and ensure that the Internal SD Card Port option is enabled and Internal SD Card

Redundancy option is set to Mirror mode.

9.

Check if the SD card is functioning properly.
If the problem persists, see

Getting Help

.

Troubleshooting Processors

1.

Remove the server module from the enclosure.

2.

Open the server module.

3.

Ensure that the processor(s) and heat sink(s) are properly installed.

4.

If your system only has one processor installed, ensure that it is installed in the primary processor socket (CPU1).

5.

Close the server module.

6.

Install the server module in the enclosure.

7.

Run the appropriate diagnostic test. For more information, see Using System Diagnostics.
If the problem persists, see

Getting Help

.

Troubleshooting The Server Module System Board

CAUTION: Many repairs may only be done by a certified service technician. You should only perform
troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or
telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your
warranty. Read and follow the safety instructions that came with the product.

1.

Remove the server module from the enclosure.

2.

Open the server module.

3.

Clear the server module NVRAM.

61