Dell PowerEdge VRTX User Manual

Page 127

Advertising
background image

Error Code

Message Information

Details

Ambient air temperature is too warm or one or more fans may have
failed.

Action

The system board <

name

> temperature is outside of the optimum

range. Check Fans.

TMP0109

Message

The memory module <

number

> temperature is greater than the upper

critical threshold.

LCD Message

Memory module <

number

> temperature is outside of range. Check

Fans.

Details

Ambient air temperature is too warm or one or more fans may have
failed.

Action

The system board <

name

> temperature is outside of the optimum

range. Check Fans.

TMP0110

Message

The memory module <

number

> temperature is outside of range.

LCD Message

Memory module <

number

> temperature is outside of range. Check

Fans.

Details

Ambient air temperature is too warm or cool.

Action

Check the system operating environment.

TMP0112

Message

The <

name

> temperature is less than the lower warning threshold.

LCD Message

The <

name

> temperature is outside of range.

Details

Ambient air temperature is too cool.

Action

Check the system operating environment.

TMP0113

Message

The <

name

> temperature is less than the lower critical threshold.

LCD Message

The <

name

> temperature is outside of range.

Details

Ambient air temperature is too cool.

Action

Check the system operating environment.

TMP0114

Message

The <

name

> temperature is greater than the upper warning

threshold.

LCD Message

The <

name

> temperature is outside of range. Check Fans

Details

Ambient air temperature is too warm or one or more fans may have
failed.

127