Dell PowerEdge VRTX User Manual

Page 95

Advertising
background image

Error Code

Message Information

Action

Review System Log or front panel for additional information.

HWC7008

Message

Server <

number

> health changed to a warning state from more

severe state. Server <

number

> health changed to a critical state from

a non-recoverable state.

Details

Server <

number

> health changed to a warning state from a normal

state.

Action

Review System Log or front panel for additional information.

HWC7010

Message

Server <

number

> health changed to a critical state from a

nonrecoverable state.

Details

Server <

number

> health changed to a warning state from a normal

state.

Action

Review System Log or front panel for additional information.

HWC7012

Message

Server <

number

> health changed to a nonrecoverable state.

Details

Server <

number

> health changed to a warning state from a normal

state.

Action

Review System Log or front panel for additional information.

LNK2700

Message

The <

name

> LAN heartbeat is lost.

Details

CMC has lost network connection.

Action

Check network cable and network connections.

MEM0000

Message

Persistent correctable memory errors detected on a memory device
at location(s) <

location

>.

Details

This is an early indicator of a possible future uncorrectable error.

Action

Re-seat the memory modules. If the issue persists, see

Getting Help

.

MEM0001

Message

Multi-bit memory errors detected on a memory device at location(s)
<

location

>.

LCD Message

Multi-bit memory error on <

location

>. Re-seat memory.

Details

The memory module has encountered a uncorrectable error. System
performance may be degraded. The operating system and/or
applications may fail as a result.

Action

Re-seat the memory modules. If the issue persists, see

Getting Help

.

95

Advertising