background image

Error Code

Message Information

a platform event (such as power down, cycle, interrupt, and send
alert).

Action

Review platform event configuration.

SEL1211

Message

The time-stamp clock could not be synchronized.

Details

The time stamp on system event log events may not correlate to the
system time.

Action

Cycle system input power. If problem persists, contact support.

SEL1300

Message

No bootable media found.

Details

System setup displays the system boot order. The local video screen
may also show additional information. (IPMI sensor type code 1eh -
offset 00h).

Action

Check system boot settings. Check if mass storage controller
configuration settings are applicable.

SEL1302

Message

Non-bootable diskette detected.

Details

The disk in the drive is not formatted correctly or does not contain the
necessary operating system files.

Action

Replace diskette with a bootable disk.

SEL1304

Message

The PXE server not found.

Details

PXE is one way to boot a system from the network.

Action

Check the network and PXE server configuration.

SEL1306

Message

Invalid boot sector found.

Details

The disk in the drive is not formatted correctly or does not contain the
necessary operating system files.

Action

Replace diskette with a bootable disk.

SEL1308

Message

A time-out occurred while waiting for user to select a boot source.

Details

The system has failed to boot to an operating system and needs the
user to select a boot source.

Action

Select boot source within the time allowed.

SEL1501

Message

Chassis management controller (CMC) redundancy is lost.

123