Dell PowerEdge VRTX User Manual

Page 128

Advertising
background image

Error Code

Message Information

Action

Check the system operating environment and review event log for fan
failures.

TMP0115

Message

The <

name

> temperature is greater than the upper critical threshold.

LCD Message

The <

name

> temperature is outside of range. Check Fans

Details

Ambient air temperature is too warm or one or more fans may have
failed.

Action

Check the system operating environment and review event log for fan
failures.

TMP0116

Message

The <

name

> temperature is outside of range.

LCD Message

The <

name

> temperature is outside of range. Check Fans

Action

Check the system operating environment and review event log for fan
failures.

TMP0118

Message

The system inlet temperature is less than the lower warning
threshold.

LCD Message

System inlet temperature is outside of range.

Details

Ambient air temperature is too cool.

Action

Check the system operating environment.

TMP0119

Message

The system inlet temperature is less than the lower critical threshold.

LCD Message

System inlet temperature is outside of range.

Details

Ambient air temperature is too cool.

Action

Check the system operating environment.

TMP0120

Message

The system inlet temperature is greater than the upper warning
threshold.

LCD Message

System inlet temperature is outside of range.

Details

Ambient air temperature is too warm or one or more fans may have
failed.

Action

Check the system operating environment and review event log for fan
failures.

TMP0121

Message

The system inlet temperature is greater than the upper critical
threshold.

128

Advertising