Error Code

Message Information

Action

If unintended, review system configuration changes and power
policy.

PWR1006

Message

The system halted because system power exceeds capacity.

LCD Message

System power demand exceeds capacity. System halted.

Details

The system halted because system power exceeds capacity.

Action

Review system configuration, upgrade power supplies or reduce
system power consumption.

PWR1007

Message

The system performance degraded because power exceeds
capacity.

LCD Message

System power exceeds capacity. Performance degraded. Check PSU
configuration.

Details

The system is currently operating in a performance degraded state to
attempt protect from a power shutdown.

Action

Review system configuration, upgrade power supplies or reduce
system power consumption.

PWR1008

Message

The system performance degraded because power draw exceeds the
power threshold.

LCD Message

System power exceeds threshold. Performance degraded. Check
PSU configuration.

Details

The power threshold is configured by the user or automatically by
software based on system configuration.

Action

Review system configuration, upgrade power supplies or reduce
system power consumption.

RFM1003

Message

Removable Flash Media <

name

> is not IPMI-function ready.

Details

The removable flash media is installed but improperly configured or
failed to initialize.

Action

If unintended, reinstall the flash media and module.

RFM1005

Message

Removable Flash Media <

name

> is not ready.

Details

The media is being prepared or is under maintenance. If the problem
persists, reinstall the card.

Action

Wait for the media to be ready.

115