Dell PowerEdge VRTX User Manual

Page 110

Advertising
background image

Error Code

Message Information

PST0143

Message

Intel Trusted Execution Technology (TXT) fatal error.

LCD Message

Intel Trusted Execution Technology (TXT) fatal error.

Details

TXT boot failed. This could be related to memory errors or an error
with the system TXT configuration. A socketed TPM module may
have been removed.

Action

Check TPM presence. Remove and reapply input power. If the issue
persists, see

Getting Help

.

PST0192

Message

Shut-down test failed.

LCD Message

Shut-down test failed. Power cycle system.

Details

System BIOS shutdown test failed during POST.

Action

Check system event log for CMOS battery exceptions. Remove and
reapply input power. If the issue persists, see

Getting Help

.

PST0193

Message

BIOS POST memory test failed.

LCD Message

BIOS POST memory test failed. Check memory devices.

Details

System BIOS POST memory test failed.

Action

Compare system memory installation to supported system memory
configurations. Reduce system configuration to minimum memory
configuration.

PST0194

Message

Remote access controller configuration failed.

LCD Message

Remote access controller configuration failed. Check screen
message.

Details

System BIOS could not configure the Remote Access controller.

Action

Cycle input power and power on the system. If the issue persists, see

Getting Help

.

PST0195

Message

CPU configuration failed.

LCD Message

CPU configuration failed. Check screen message.

Details

The current processor configuration is unsupported or encountered a
fatal exception during POST.

Action

Review system processor configuration and reduce the system to the
minimum configuration.

PST0196

Message

Incorrect memory configuration.

110

Advertising