Dell PowerEdge VRTX User Manual

Page 81

Advertising
background image

Error Code

Message Information

Details

The system board battery is either missing, bad, or unable to charge
due to thermal issues.

Action

Check system fans. Replace the system board battery.

BAT0002

Message

The system board battery has failed.

LCD Message

The system board battery has failed. Check battery.

Details

The system board battery is either missing or bad.

Action

See

Getting Help

.

BAT0004

Message

The system board battery is absent.

LCD Message

The system board battery is absent. Check battery.

Action

Reinstall the system board battery.

BAT0005

Message

The storage battery is low.

Details

System has to remain powered on to charge the battery.

Action

Allow the battery to charge. If the issue persists, see

Getting Help

.

BAT0007

Message

The storage battery has failed.

LCD Message

The storage battery has failed. Check battery.

Details

Verify the cable connection between the storage battery and the
controller.

Action

Verify the storage battery installation.

BAT0010

Message

The storage battery for disk drive bay <

bay

> is low.

Details

System has to remain powered on to charge the storage battery.

Action

Allow the storage battery to charge. If the issue persists, see

Getting

Help

.

BAT0012

Message

The storage battery for disk drive bay <

bay

> has failed.

LCD Message

Battery for disk drive bay <

bay

> has failed. Check battery.

Details

Verify the cable connection between the storage battery and the
controller.

Action

Verify the storage battery installation.

BAT0014

Message

The storage battery for disk drive bay <

bay

> is absent.

81