Error Code

Message Information

Action

Cycle input power, update component drivers, remove and reinstall
the device at the next scheduled service time.

PDR0001

Message

Fault detected on drive <

number

>.

LCD Message

Fault detected on drive <

number

>. Check drive.

Details

The controller detected a failure on the disk and has taken the disk
offline.

Action

Remove and re-seat the failed disk. If the issue persists, see

Getting

Help

.

PDR0002

Message

A predictive failure detected on drive <

number

>.

Details

The controller received a SMART error from the drive. The drive is
operational but needs replacement.

Action

The drive will need replacement at the next service window.

PDR0016

Message

Drive <

number

> is removed.

LCD Message

Drive <

number

> is removed. Check drive.

Details

The controller detected a drive removal.

Action

If unintended, verify drive installation. Remove and re-seat the
indicated disk. If the issue persists, see

Getting Help

.

PDR1001

Message

Fault detected on drive <

number

> in disk drive bay <

bay

>.

LCD Message

Fault detected on drive <

number

> in disk drive bay <

bay

>. Check

drive.

Details

The controller detected a failure on the disk and has taken the disk
offline.

Action

Re-seat the failed drive. If the issue persists, see

Getting Help

.

PDR1002

Message

A predictive failure detected on drive <

number

> in disk drive

bay<

bay

>.

Details

The controller received a SMART error from the drive. The drive is
operational but needs replacement.

Action

The drive will need replacement at the next service window.

PDR1016

Message

Drive <

number

> is removed from disk drive bay <

bay

>.

LCD Message

Drive <

number

> removed from disk drive bay <

bay

>. Check drive.

106

Advertising