Error Code

Message Information

Details

The current power operational mode is non-redundant because of a
power supply exception, a power supply inventory change, or a
system power inventory change.

Action

Check the event log for power supply failures. Review system
configuration and power consumption.

PWR1001

Message

The system performance was degraded.

LCD Message

System performance degraded. Check PSUs and system
configuration.

Details

To avoid shutdown, system performance has been degraded.

Action

Review system configuration and system logs for thermal or
environmental failures and warnings.

PWR1002

Message

The system performance degraded because of thermal protection.

Details

To avoid shutdown, system performance has been degraded.

Action

Review system configuration and system logs for thermal or
environmental failures and warnings.

PWR1003

Message

The system performance degraded because cooling capacity has
changed.

Details

The current power supply configuration does not meet the platform
requirements to enable redundancy. If a power supply fails the
system may shutdown.

Action

If unintended, review system configuration and power consumption
and install power supplies accordingly. Check power supply status
for failures.

PWR1004

Message

The system performance degraded because power capacity has
changed.

Details

The system may power down or operate in a performance degraded
state.

Action

Check the event log for power supply failures. Review system
configuration and power consumption and upgrade or install power
supplies accordingly.

PWR1005

Message

The system performance degraded because the user-defined power
capacity has changed.

Details

The user-defined power settings have affected system operation.