Error Code

Message Information

MEM1012

Message

Memory device at location <

location

> is in a degraded state.

Details

The memory may not be operational. This an early indicator of a
possible future uncorrectable error.

Action

Re-seat the memory modules. If the issue persists, see

Getting Help

.

MEM1016

Message

Memory device at location <

location

> is not installed correctly.

LCD Message

Memory <

location

> is not installed correctly. Reinstall.

Details

The memory may not be seated correctly, misconfigured, or has
failed. Memory size is reduced.

Action

Check the memory configuration. Re-seat the memory modules. If the
issue persists, see

Getting Help

.

MEM1205

Message

Memory mirror redundancy is lost. Check memory device at
location(s) <

location

>.

LCD Message

Memory mirror lost on <

location

>. Power cycle system.

Details

The memory may not be seated correctly, misconfigured, or has
failed.

Action

Check the memory configuration. Re-seat the memory modules. If the
issue persists, see

Getting Help

.

MEM1206

Message

Memory mirror redundancy is degraded. Check memory device at
location <

location

>.

Details

The memory may not be seated correctly, misconfigured, or has
failed.

Action

Check the memory configuration. Re-seat the memory modules. If the
issue persists, see

Getting Help

.

MEM1208

Message

Memory spare redundancy is lost. Check memory device at location
<

location

>.

LCD Message

Memory spare lost on <

location

>. Power cycle system.

Details

Memory sparing is no longer available.

Action

Re-seat the memory modules. If the issue persists, see

Getting Help

.

MEM1212

Message

Memory redundancy is lost.

Details

The memory may not be seated correctly, misconfigured, or has
failed.