Error Code

Message Information

LCD Message

CPU <

number

> has a thermal trip. Check CPU heat sink.

Details

The processor temperature increased beyond the operational range.

Action

Review logs for fan failures, replace failed fans. If no fan failures are
detected, check inlet temperature (if available) and reinstall
processor heat-sink.

CPU0002

Message

CPU <

number

> has failed the built-in self-test (BIST).

Action

1. Turn system off and remove input power for one minute.

Reapply input power and turn system on.

2. Make sure the processor is seated correctly.
3. If the issue persists, see

Getting Help

.

CPU0003

Message

CPU <

number

> is stuck in POST.

Action

1. Turn system off and remove input power for one minute.

Reapply input power and turn system on.

2. Reduce system configuration to minimum memory and remove

all PCI devices. If system completes POST, update system BIOS.

reinstall memory and PCI one component at a time to meet the

original configuration.

3. If the issue persists, see

Getting Help

.

CPU0004

Message

CPU <

number

> failed to initialize.

Action

1. Turn system off and remove input power for one minute.

Reapply input power and turn system on.

2. Make sure the processor is seated correctly.
3. If the issue persists, see

Getting Help

.

CPU0005

Message

CPU <

number

> configuration is unsupported.

LCD Message

CPU <

number

> configuration is unsupported. Check CPU or BIOS

revision.

Details

System is unable to boot or may run in a degraded state.

Action

Review the technical specifcations for supported processor types.

CPU0006

Message

Unrecoverable CPU complex error detected on CPU <

number

>.

Details

System is unable to boot or may run in a degraded state.

83