Dell PowerEdge VRTX User Manual

Page 124

Advertising
background image

Error Code

Message Information

Details

An action or failure has taken place that breaks CMC redundancy.

Action

Check the CMC network cables and network connections. Check that
CMC firmware versions match.

SEL1502

Message

Chassis management controller (CMC) redundancy is degraded.

Details

An action or failure has taken place that breaks CMC redundancy.

Action

Check the CMC network cables and network connections. Check that
CMC firmware versions match.

SEL1504

Message

The chassis management controller (CMC) is not redundant.
Insufficient resources to maintain normal operations.

Details

There is not enough available power for two CMC's to operate.

Action

Check the overall power consumption and power status.

SEL1506

Message

Lost communications with Chassis Group Member <

number

>.

Details

The primary CMC has lost communication with the indicated member
CMC.

Action

Check the network cable and network connections.

SEL1508

Message

Member <

number

> could not join the Chassis Group.

Details

The indicated member CMC is a leader of a different CMC stacking
group.

Action

Check if member CMC is a leader of a different chassis group.

SEL1510

Message

An authentication error detected for Chassis Group Member
<

number

>.

Details

Group master CMC could not log into the group member CMC.

Action

Check the login credentials of CMC.

SEL9900

Message

An unsupported event occurred.

Details

The current software version cannot decode this event. You may
need to review this event using a tool which displays raw data such
as Ipmitool with the -vvv option or Racadm with the -E option.

Action

Upgrade the management software.

124