Error Code

Message Information

SWC4004

Message

A firmware or software incompatibility detected between iDRAC in
slot <

number

> and CMC.

Details

FlexAddress is not implemented in one of the versions of firmware.

Action

Check the firmware versions of iDRAC and CMC. Update with the
latest version.

SWC4006

Message

A firmware or software incompatibility detected between system
BIOS in slot <

number

> and CMC.

Details

FlexAddress is not implemented in one of the versions of firmware.

Action

Check the firmware versions of BIOS and CMC. Update with the latest
version.

SWC4008

Message

A firmware or software incompatibility detected between CMC 1 and
CMC 2.

Details

FlexAddress is not implemented in one of the versions of firmware.
Please update the firmware.

Action

Check firmware versions. Update CMC 1 and CMC 2 firmware to
match.

SWC5001

Message

<

name

> upgrade failed.

Action

Reboot the system and attempt the upgrade again.

TMP0100

Message

The system board <

name

> temperature is less than the lower

warning threshold.

LCD Message

System board <

name

> temperature is outside of range.

Details

Ambient air temperature is too cool.

Action

Check the system operating environment.

TMP0101

Message

The system board <

name

> temperature is less than the lower critical

threshold.

LCD Message

System board <

name

> temperature is outside of range.

Details

Ambient air temperature is too cool.

Action

Check the system operating environment.

TMP0102

Message

The system board <

name

> temperature is greater than the upper

warning threshold