Swsensorscn 1.3.6.1.4.1.1588.2.1.1.1.0.2, Swfcportscn 1.3.6.1.4.1.1588.2.1.1.1.0.3 – Dell POWEREDGE M1000E User Manual

Page 174

Advertising
background image

156

Fabric OS MIB Reference

53-1001768-01

swSensorScn 1.3.6.1.4.1.1588.2.1.1.1.0.2

5

swSensorScn 1.3.6.1.4.1.1588.2.1.1.1.0.2

(Obsoleted by swFabricWatchTrap)

Enterprise

sw

Variables

“swSensorStatus 1.3.6.1.4.1.1588.2.1.1.1.1.22.1.3”

“swSensorIndex 1.3.6.1.4.1.1588.2.1.1.1.1.22.1.1”

“swSensorType 1.3.6.1.4.1.1588.2.1.1.1.1.22.1.2”

“swSensorValue 1.3.6.1.4.1.1588.2.1.1.1.1.22.1.4”

“swSensorInfo 1.3.6.1.4.1.1588.2.1.1.1.1.22.1.5”

“swSsn 1.3.6.1.4.1.1588.2.1.1.1.1.10”

A swSensorScn (2) is generated whenever an environment sensor changes its operational state: for
instance, if a fan stop working. The VarBind in the Trap Data Unit contain the corresponding
instance of the sensor status, sensor index, sensor type, sensor value (reading), and sensor
information. Note that the sensor information contains the type of sensor and its number, in textual
format.

swFCPortScn 1.3.6.1.4.1.1588.2.1.1.1.0.3

Enterprise

sw

Variables

“swFCPortOpStatus 1.3.6.1.4.1.1588.2.1.1.1.6.2.1.4”

“swFCPortIndex 1.3.6.1.4.1.1588.2.1.1.1.6.2.1.1”

“swFCPortName 1.3.6.1.4.1.1588.2.1.1.1.6.2.1.36”

“swSsn 1.3.6.1.4.1.1588.2.1.1.1.1.10”

“swFCPortFlag 1.3.6.1.4.1.1588.2.1.1.1.6.2.1.38”

“swVfId 1.3.6.1.4.1.1588.2.1.1.1.2.15”

A swFCPortScn (3) is generated whenever an FC port changes its operational state: for instance,
the FC port goes from online to offline. The VarBind in the Trap Data Unit contain the corresponding
instance of the FC port's operational status, index, swFCPortName, and swSsn. swFCPortName
and swSsn are optional.

#TYPE

A sensor (temperature, fan, or other) changed its
operational state.

#SUMMARY

%s: is currently in state %d and SSN is #%s

#ARGUMENTS

4, 0, 5

#SEVERITY

Informational

#TIMEINDEX

1

#STATE

Operational

Advertising