background image

Fabric OS MIB Reference

15

53-1001768-01

Loading Brocade MIBs

1

swFabricWatchTrap: YES

DesiredSeverity:None

swTrackChangesTrap: YES

swIPv6ChangeTrap: YES

swPmgrEventTrap: YES

swFabricReconfigTrap: YES

swFabricSegmentTrap: YES

swExtTrap: YES

FA-TRAP: YES

connUnitStatusChange: YES

connUnitDeletedTrap: YES

connUnitEventTrap: YES

connUnitSensorStatusChange: YES

connUnitPortStatusChange: YES

FICON-TRAP: YES

linkRNIDDeviceRegistration: YES

linkRNIDDeviceDeRegistration: YES

linkLIRRListenerAdded: YES

linkLIRRListenerRemoved: YES

linkRLIRFailureIncident: YES

HA-TRAP: YES

fruStatusChanged: YES

cpStatusChanged: YES

fruHistoryTrap: YES

ISCSI-TRAP: YES

iscsiTgtLoginFailure: YES

iscsiIntrLoginFailure: YES

iscsiInstSessionFailure: YES

IF-TRAP: YES

linkDown: YES

linkUp: YES

BD-TRAP: YES

bdTrap: YES

bdClearTrap: YES

Example of systemGroup configuration (default)

switch:admin> snmpconfig --default systemGroup

*****

This command will reset the agent's system group configuration back to

factory default

*****

sysDescr = Fibre Channel Switch

sysLocation = End User Premise

sysContact = Field Support

authTraps = 0 (OFF)

*****

Are you sure? (yes, y, no, n): [no] y

3. Set the security level.

switch:admin> snmpconfig --set secLevel

Select SNMP GET Security Level

(0 = No security, 1 = Authentication only, 2 = Authentication and Privacy, 3 =

No Access): (0..3) [0] 2

Select SNMP SET Security Level

(0 = No security, 1 = Authentication only, 2 = Authentication and Privacy, 3 =

No Access): (2..3) [2] 2

switch:admin> snmpconfig --show secLevel

GET security level = 2, SET level = 2