Swflashdlpassword 1.3.6.1.4.1.1588.2.1.1.1.1.16, Swbeaconoperstatus 1.3.6.1.4.1.1588.2.1.1.1.1.18, Swbeaconadmstatus 1.3.6.1.4.1.1588.2.1.1.1.1.19 – Dell POWEREDGE M1000E User Manual

Page 183: Swdiagresult 1.3.6.1.4.1.1588.2.1.1.1.1.20, Swnumsensors 1.3.6.1.4.1.1588.2.1.1.1.1.21

Advertising
background image

Fabric OS MIB Reference

165

53-1001768-01

swFlashDLPassword 1.3.6.1.4.1.1588.2.1.1.1.1.16

5

This OID cannot be used for either firmwareDownload or configDownload (cannot be set and is
read-only) for Fabric OS v4.4 and above. The value displayed is always NULL (zero-length).This is
not supported in v6.0.0 and higher versions.

swFlashDLPassword 1.3.6.1.4.1.1588.2.1.1.1.1.16

The password to be used for FTP transfer of files in the download or upload operation.

This OID cannot be used for either firmwareDownload or configDownload (cannot be set and is
read-only) for Fabric OS v4.4 and above. The value displayed is always NULL (zero-length).This is
not supported in v6.0.0 and higher versions.

swBeaconOperStatus 1.3.6.1.4.1.1588.2.1.1.1.1.18

The current operational status of the switch beacon.

Values

Possible values are:

on (1) The LEDs on the front panel of the switch run alternately from left to right and right to
left. The color is yellow.

off (2) Each LED is in its regular status, indicating color and state.

swBeaconAdmStatus 1.3.6.1.4.1.1588.2.1.1.1.1.19

The desired status of the switch beacon.

Values

Possible values are:

on (1) The LEDs on the front panel of the switch run alternately from left to right and right to
left. Set the color to yellow.

off (2) Set each LED to its regular status, indicating color and state.

swDiagResult 1.3.6.1.4.1.1588.2.1.1.1.1.20

The result of the power-on startup test (POST) diagnostics.

Values

Possible values are:

sw-ok (1) The switch is okay.

sw-faulty (2) The switch has experienced an unknown fault.

sw-embedded-port-fault (3) The switch has experienced an embedded port fault.

swNumSensors 1.3.6.1.4.1.1588.2.1.1.1.1.21

The number of sensors inside the switch.

The Brocade DCX value is between 1 and 57 (temperature =50, fan = 3, power supply = 4). The
value might vary depending on the switch model. For Fabric OS v6.1.0, if no sensor is available, this
variable is assigned the value -1.

Advertising