Fabric OS MIB Reference

53-1001768-01

connUnitPortStatus 1.3.6.1.3.94.1.10.1.7

8

•

unavailable (1) Do not use.

•

online (2) Available for meaningful work.

•

offline (3) Not available for meaningful work.

•

bypassed (4) No longer used.

•

diagnostics (5) Map to your testing. (Not supported in Fabric OS v2.6.1.)

For an E, F, or FL_Port, the value is online. For a U_Port, the value is offline (disabled, testing,
faulted).

connUnitPortStatus 1.3.6.1.3.94.1.10.1.7

An overall protocol status for the port. For a U_Port, the status should be ols (9).

Values

Possible values are:

•

unknown (1)

•

unused (2) Device cannot report this status.

•

ready (3) FCAL Loop or FCPH Link reset protocol initialization has completed.

•

warning (4) Do not use.

•

failure (5) Port is faulty.

•

notparticipating (6) Loop not participating and does not have a loop address. Do not use.

•

initializing (7) Protocol is proceeding. Do not use.

•

bypass (8) Do not use.

•

ols (9) FCP offline status. (Not supported in Fabric OS v2.6.1.)

NOTE

In Fabric OS v2.6.x, for an E_Port, F_Port, or FL_Port, the value is 3 (ok). For a U_Port, the value is 2
(unused) if not faulty with GBIC, 1(unknown) if not faulty but no GBIC, or 5 (failure) if faulty.

In Fabric OS v3.x and above, for an E_Port, F_Port, FL_Port or other Port and online port state, the
value is 3 (ok). For G_Port or other Port and offline port state, the value is 9 (ols). For unknown
portype and offline port state, the value is 1 (unknown).

connUnitPortTransmitterType 1.3.6.1.3.94.1.10.1.8

The technology of the port transceiver.

Values

Possible values are:

•

unknown (1)

•

other (2)

•

unused (3)

•

shortwave (4)

•

longwave (5)

•

copper (6)

•

scsi (7)

Advertising