Storage controller card (service only), Removing the storage controller board, Through step 7 – Dell PowerEdge M600 User Manual

Page 154: D. see "removing the storage

Advertising
background image

154

Installing Blade Components

4 Replace the mezzanine card(s) in their original locations. See "Installing a

Mezzanine Card" on page 124.

5 Reinstall the hard-drive backplane. See "Hard-Drive Backplane" on page 148.
6 Replace the hard drive(s).

If there are two drives, be sure and reinstall them in their original
locations.

If only one hard-drive is installed, install it in bay 0.

7 Close the blade. See "Closing the Blade" on page 104.
8 Remove the plastic I/O connector covers from the back of the blade.
9 Install the blade in the system. See "Installing a Blade" on page 98.

Storage Controller Card (Service Only)

The storage controller board is located underneath the drive bays.

Removing the Storage Controller Board

1 Remove the blade. See "Removing a Blade" on page 96.
2 Open the blade. See "Opening the Blade" on page 100.
3 Remove the system board and place it on the work surface. See "Removing

the System Board" on page 150.

4 Open the release lever to disengage the controller board edge connector

from the system board connector.

5 Lift the controller board straight up from the system board.

Advertising