Dell PowerEdge M600 User Manual

Page 36

Advertising
background image

36

About Your System

To tier the iKVM switch module from a Dell 2161DS, 180AS, or 2160AS
console switch:

If the switch does not require a SIP to connect to the iKVM (see Table 1-9),
connect a Cat5 (or newer) cable to the RJ-45 ACI port on the iKVM
module. See Figure 1-13.

Connect the other end of this cable to the ARI port on the external switch.

If the switch requires a USB SIP (see Table 1-8), connect a USB SIP to the
iKVM, then connect a a Cat5 (or newer) cable to the SIP. Connect the
other end of this cable to the ARI port on the external switch.

Once the KVM switch is connected, the server modules appear in OSCAR.

NOTE:

Once the local system is set up, you must also resynchronize the server list

from the Remote Console Switch software in order to see the list of blades. See
Resynchronizing the Server List at the Remote Client Workstation.

Resynchronizing the Server List at the Remote Client Workstation

Once the iKVM switch is connected, the blades appear in OSCAR. You now
need to resynchronize the servers on any remote workstation to ensure that
the blades are available to any remote users connected to the console switch
through the Remote Console Switch software.

NOTE:

This procedure only resynchronizes one remote client workstation. With

multiple client workstations, save the resynchronized local database and load it into
the other client workstations to ensure consistency.

To resynchronize the server listing:

1 Click Resync in the Server category of the Management Panel (MP).

The Resync Wizard launches.

2 Click Next.

A warning message displays indicating that the database will be updated to
match the current configuration of the console switch. Your current local
database names will be overridden with the switch names. To include
unpowered SIPs in the resynchronization, click to enable the Include
Offline SIPs check box.

3 Click Next.

A Polling Remote Console Switch message box appears with a progress
bar indicating that the switch information is being retrieved.