Installing Enclosure Components

NOTICE:

A Torx T15 driver is required for this procedure.

1 Press the system power switch to turn off the system. See "System Control

Panel Features" on page 14.

NOTICE:

To avoid damaging the modules, you must remove all the modules

installed in the enclosure before removing the front module cage assembly and
midplane.

NOTICE:

If you remove the chassis from the rack, you must remove all modules

before moving the chassis. Do not use the LCD display as a handle when moving the
chassis.

2 Remove all of the blades. See "Removing a Blade" on page 96.
3 Remove the power supply modules. See "Removing a Power Supply

Module" on page 159.

4 Remove the fan modules. See "Removing a Fan Module" on page 161.
5 Remove the CMC module(s). See "Removing a CMC Module" on

page 162.

6 Remove the iKVM module. See "Removing an iKVM Module" on

page 166.

7 Remove the I/O modules. See "Removing an I/O Module" on page 166.
8 Remove the four screws securing the front module cage assembly to the

enclosure. See Figure 4-8.