4.3 Navigating the Weigh Mode

4.3.1 Enter the Weigh Mode

Press the [HOLD] + [UNIT] keys for 3 seconds. Use the [UNIT] key to choose the
desired mode and the [TARE] key to confirm selection and exit to the chosen mode.

4.3.2 Enter or Exit the HOLD Mode

Press the [HOLD] key for 3 seconds.

4.3.3 Zero

When the weight is stable and within the zero range, press the [ZERO] key to set a new
zero point. Refer to

Table 4.3

for zero limitations.

4.3.4 Tare

When the gross weight is larger than zero and the scale is stable, press the [TARE]
key. The indicator will show a net weight of zero and the NET annunciator will be
illuminated. Refer to

Table 4.3

for tare limitations.

4.3.5 Preset Tare Weight

Enter a preset tare weight by pressing the [TARE] key for more than 3 seconds.
Pr.Tar will be displayed and the NET annunciator flashes. Use the [UNIT] and
[TARE] key to input the desired tare weight and the [HOLD] key to move to the next
digit. The value entered must be larger than zero and there is no limitation to preset
tare weight. After the tare weight is entered the NET annunciator will illuminate. Refer
to

Table 4.3

for tare limitations.

Note: This indicator can only save one tare weight. The new tare weight will
automatically replace the old one.

4.3.6 Clear Tare Weight

Remove any weight on platform and wait until the scale is stable. Press the [TARE] key.

Table 4.3 Zero and Tare Limitations

Standard

Weight on

platform

Data in TARE

memory unit

key function

Tare key

Zero key

USA

≤0

no

No action

Zero

yes

Clear the tared weight

>0

no

Tare

yes

Advertising