3 cal menu, Cal menu – Salter Brecknell 6700U Series (USB) User Manual

Page 51

Advertising
background image

67XXU USB/Serial Scale Service Manual

51

5.3.3 CAL Menu

Figure 5.3 CAL Menu Chart

The figure above is an illustration of the available menus with the CAL menu and the
choices within those menus. Refer to

Table 5.4

for explanations of the menu choices.

Table 5.4 CAL Menu Choices and Explanations

CAL.ON
CA.OFF

ZERO

LINE

GEO

INPUT

CODE

GRAVT

00-70

9.76183-

9.99999

CAL.PO

CAL.P1

END.Y

CAL.P2

END.Y

CAL.P3

Yes

No

Yes

No

CAL

Submenu1

Submenu2

Option Parameter Description

Comment

CAL.ON
CA.OFF

Seal switch position

The display will show whether the
seal switch is in the ON or Off
position. This parameter can’t be
changed within the software.

ZERO

Zero point calibration

Only do zero point calibration, then
go to CAL.END to end (only need
where a zero shift has occurred).