67XXU USB/Serial Scale Service Manual

39

ZRO.PT

IZSM

0-100

10

Initial zero set
mechanism

Range of capacity in percent
± 0 - 100%FS
Also uses SAZSM and AZSM (total)
*If (REGUL)=none, the max is 10

IN.IZS

WEGHT

WEGHT Inside IZSM

WEIGHT= on power up

CAL.ZR

CAL.ZR= calibration zero point

LST.Z.T

LST.Z.T=store last push button zero
and push button tare
*If (REGUL) ≠none, the value is
fixed on WEIGHT

OV.IZS

DP.OVR

DP.OVR Outside IZSM

DP.OVR=display initial zero is over.
Display will show upper dashes
when above capacity

WEGHT

WEIGHT= current weight
Can zero more weight (approx 90%)
before dashes are displayed. Not
Legal for Trade

CAL.ZR

CAL.ZR= calibration zero point
will display dashes at 100%

LST.Z.T

LST.Z.T=Last ZERO and TARE

SAZSM

0-100

2

Zero key range

0=no limitation
1-100= (initial zero point) ±1%FS -
(initial zero point) ±100%FS
*If (REGUL) ≠none, the max is 2

AZSM

0-100

8

Zero tracking window

0=0d, no tracking
1-100=±(0.2+0.05*(1-100))d /s
*If (REGUL) ≠none, the max is 4

FLTER

FT1.TH 0-255

40

Digital filter1 threshold

0=no filter1
1-254=filter1 used only when
vibration in ±0.25d*(1-254)
255= filter1 always used

FT1.ST

weak

midle Digital filter1 intensity

Weak = 4 weights to average
Midle = 8 weights to average
Strong = 16 weights to average

midle

stong

FT2.TH

0-255

8

Digital filter2 threshold

0=no filter2
1-254=filter2 used only when
vibration in ±0.25d*(1-254)
255= filter2 always used

FT2.ST

0-255

240

Digital filter2 intensity

0-255=weak to strong

CONFG

SubMenu1

SubMenu2

Option

Default

Parameter Description

Comment