4.4.2 Obtain Piece Weight

There are two ways to obtain the piece weight:

Input Piece Weight Directly

1.

Press the [UNIT] key.

2.

When

InP.PW is displayed, press the [TARE] key to enter into the piece

weight mode.

3.

When

UNIT.KG is shown, use the [UNIT] key to select the unit of piece

weight.

4.

Use the [TARE] key to confirm and go to piece weigh entry. The display will
show

L0001 (Note: Since the LCD can only show 4 digits, but the software

allows 6 digits total, so there will be separate displays:

L0001 and H00,

L0001 displays the low position digits and H00 displays the high position
digits).

5.

From the

L0001 display, use [HOLD] and [UNIT] key to input new piece

weight.

5a.

Press the [UNIT] key to increase the numbers.

5b.

Press the [HOLD] key to change the flashed position.

5c.

Press the [HOLD] key more than 3 seconds to input decimal point.

5d.

If the input piece weight is less than 0.5d, the indicator will display

PWt.Er

and go back to counting mode.

6.

Press the [TARE] key to confirm the entry.

7.

Press the [ZERO] key to exit the piece weight mode and back to counting
mode.

Sample a Known Quantity

1.

Press the [UNIT] key.

2.

When

In.PWt is shown, use the [UNIT] key to select SPL.lo.

3.

Press the [TARE] key to weigh samples (which quantity is known) weight,
calculate piece weight.

4.

When

SPL.Lo is shown, remove the sample on scale and press the [TARE]

key to confirm. Before scale is stable,

SPL.Lo will be flashed. After it is stable,

it will go to next step.

5.

When

SPL.Hi is shown, put samples (if quantity is known) onto the scale,

Press the [TARE] key to confirm reading weight. Before scale is stable,
SPL.hi will be flashed. After it is stable, it will go to next step.

5a.

If the calculated piece weight is less than 0.5d, the indicator will display
PWt.Er and go back to counting mode. Otherwise, after the reasonable piece
weight has been captured, the scale will go back to counting mode. The piece
weight will be saved and used again.

6.

After

IN.PCS shown, L0000 will be displayed.

7.

Use the [UNIT] and [HOLD] keys to input the quantity of samples.

Advertising