Salter Brecknell 6700U Series (USB) User Manual

Page 50

Advertising
background image

50

67XXU USB/Serial Scale Service Manual

OTHER

NLD.RG

1-255

10

No hold range

Load must return to zero in
divisions to perform a print when in
AUTO.
1-255=the range of weight is 1-
255d. When current weight is less
than this value, the scale can be
regarded as empty, or the load on
scale is removed.
It must be bigger than
(CONFG.MOTON).

CMD.SR

NONE

COM1.2

Command source
Turns COM1 / COM2 on/off

(1) NONE=no any command will be
executed

COM.1

(2) COM.1= command from COM1
will be executed

COM.2

(3) COM.2= command from COM2
will be executed

COM1.2

(4) COM.1.2= command from
COM1 or COM2 will be executed

Legacy

0-2

1

Status bit setting

0=no change to output string. Can
send 3 or 4 status bits

1=all data sent ot has 2 status bits =
bit 6. Character 2 must be set to 0

2=all data sent out has 3 status bits
and 7 weight characters.

A.OFF.T

0-255

0

Auto off time

0=not auto power off
1-255=auto power off after 1-255
minutes. In this period, no operation
or no weight change

LCD.BL

0-255

30

LCD backlight set

(1) 0=always off
(2) 1=always on
(3) 2=press down ZERO+UNIT
together more than 3s to turn on or
turn off
(4) 3-255=auto on when key
operation or weight changing. Auto
off after 3-255s elapsed.

TA.key

yes

yes

Tare key enable

Yes= tare key is enabled

no

No= tare key is disabled

phd.rg

0-8

0

Photo eye TARE sensitivity

(1) 0= remote TARE key disabled
(2) 1-8 = sensitivity level
1= close distance - 8= long distance

SCL.ID 000000-

999999

123456 Scale ID number: 000000-

999999

USER

SubMenu1 SubMenu2

Option

Default

Parameter Description

Comment