67XXU USB/Serial Scale Service Manual

Command: H (48h)

Command: A (41h)

Command: B (42h)

Command: E (45h)

Response

Send high resolution weight dat (x10)
<STX>W

1

W

2

<dp>W

3

W

4

W

5

<CR>---normal data

Note: (1) The decimal point position is determined by CONFG-PRIM.D
(2) If current unit is "lb:oz", the format will be similar with following:
<STX>W

1

W

2

W

3

lbW

4

W

5

W

6

<dp>W

7

oz<CR>

Response

Scale initiates a test of RAM, ROM and NOVRAM. Places the result into confidence
test status byte for future interrogation by the host. It also returns acknowledgement.
<STX>?<CR>

Response

Send confidence test result status byte of previously performed test (Command A).
<STX>[confidence]<CR>

Bit

Confidence

0

always 0

1

0= NOVROM Test Pass
1= NOVROM Test Fail

2

always 0

3

0= RAM Test Pass
1= RAM Test Fail

4

0= ROM Test Pass
1= ROM Test Fail

5

always 0

6

0= New Status Read
1= New Status Available

7

parity

Response

Scale is placed in echo mode. All subsequent characters (except F) are not treated
as commands. These characters are echoed back to the host.
<STX>E<CR>