Salter Brecknell 6700U Series (USB) User Manual

Page 68

Advertising
background image

68

67XXU USB/Serial Scale Service Manual

Command: <ENQ><CR> (05h 0dh)

Command: all others

Table 7.4 Summary of Command and Response:

Response

Depends on the scale and protocol.
<LF>OPOS<CR><ETX>
OPOS - enabled scale

Response

Unrecognized command
<LF>? <CR><ETX>

Command

Response

ASCII

HEX

W<CR>

57 0d

Read scale weight:
<LF>^^^^^^^^U

1

U

2

U

3

U

4

U

5

<CR><LF>S H

1

H

2

H

3

H

4

<CR><ETX>---over capacity

<LF>________U

1

U

2

U

3

U

4

U

5

<CR><LF>S H

1

H

2

H

3

H

4

<CR><ETX>---under capacity

<LF>-------- U

1

U

2

U

3

U

4

U

5

<CR><LF> S H

1

H

2

H

3

H

4

<CR><ETX>---zero-point error

<LF><P>W

1

W

2

W

3

W

4

W

5

<DP>W

6

U

1

U

2

U

3

U

4

U

5

<CR><LF> S H

1

H

2

H

3

H

4

<CR><ETX>---normal data

S<CR>

53 0d

<LF> S H

1

H

2

H

3

H

4

<CR><ETX>; read scale status

Z<CR>

5a 0d

<LF> S H

1

H

2

H

3

H

4

<CR><ETX>; simulate ZERO key

U<CR>

55 0d

<LF>U

1

U

2

U

3

U

4

U

5

<CR><LF> S H

1

H

2

H

3

H

4

<CR><ETX>; simulate UNIT key

u<CR>

75 0d

<LF> x<CR><ETX>

A<CR>

41 0d

<LF>vwxyz<CR><ETX>

m<CR>

6d 0d

<LF>xx<CR><ETX>

<ENQ><CR>

05 0d

<LF>OPOS<CR><ETX>

L<CR>

4c 0d

<LF>H

1

H

2

H

3

H

4

<CR><ETX>; simulate HOLD key

X<CR>

58 0d

Power off the scale, simulate OFF key

others

<LF>? <CR><ETX>

Advertising