67XXU USB/Serial Scale Service Manual

PRIM.Ut

kg

lb

Primary unit

Select the primary unit from kg or lb.
The second unit is lb if kg is
selected as the primary unit.
*The calibration standard weight
must be in the primary unit!

lb

SECD.N

100-

25000

Second scale full scale
value

The division number under second
unit. The maximum is
1.25*(PRIM.N).
*If (REGUL)≠none, the max is
10,000
NOTE: Secondary division has to
match the primary division.

10.DSP

NO

NO

Display weight at 10
times division number
under primary unit

*If (REGUL)= none this parameter
will not be available.
When yes is selected, some
menus will not be active.

YES

MOTON

1-255

4

Motion window

1-255 = ±0.25d *(1-255)
*If (REGUL)=none, the max is 12

OVER.D

0-100

0

Overload display
limitation

0=FS+9d
1-100=101%FS -200%FS.
*If (REGUL)=none, the max is 10

UNITS

KG

yes

yes

UNITS key

YES = enable this unit
No = disable this unit

In trade applications, lb:oz is not
allowed

no

lb

yes

yes

no

oz

yes

yes

no

lb:oz

yes

no

no

g

yes

yes

no

CONFG

SubMenu1

SubMenu2

Option

Default

Parameter Description

Comment