Salter Brecknell 6700U Series (USB) User Manual

Page 77

Advertising
background image

67XXU USB/Serial Scale Service Manual

77

Command: <US> F (1Fh 46h)

Command: all others

Table 7.9 Summary of Command and Response:

Response

Scale is taken out of echo mode. All subsequent characters are commands.
<STX>F<CR>

Response

Unrecognized command
<STX>?[status]<CR>

Command

Response

ASCII

HEX

<US> W

1F 57 1. normal data

<STX>W

1

W

2

<dp>W

3

W

4

W

5

<CR>

2. if current weight is invalid
<STX>?<Status Byte><CR>

<US> Z

1F 5a <STX>?[status]<CR>

<US> H

1F 48 1. normal data

<STX>W

1

W

2

<dp>W

3

W

4

W

5

W

6

<CR> -- weight data (x10)

2. if current weight is invalid
<STX>?<Status Byte><CR>

<US> A

1F 41 <STX>?<CR>

<US> B

1F 42 <STX>[confidence]<CR?>

<US> E

1F 45 <STX>E<CR>

<US> F

1F 46 <STX>F<CR>

others

<STX>?[status]<CR>