67XXU USB/Serial Scale Service Manual

45

COM2

(9 Pin)

BUD.RT

1200

9600

Select COM2 baud rate

2400

4800

9600

19200

38400

BT.FMT

8N1

7e1

Select COM2 byte format

(1) 8N1=8 data bits, No parity check
bit, 1 stop bit

7O1

(2) 7O1=7 data bits, 1 Odd parity
check bit, 1 stop bit

7E1

(3) 7E1=7 data bits, 1 Even parity
check bit, 1 stop bit

OUT.MD

none

PRT.CD

Select COM2 output mode

(1) NONE=no communication

CONT

(2) CONT=continuously output

PRINT

(3) PRINT=output after PRINT key
pressed

CMD

(4) CMD=output after a request
command is received

PRT.CD

(5) PRT.CD= output after PRINT
key pressed or request command
received

STABL

(6) STABL=output after scale is
stable; Note: use PRINT or CMD to
output data, the scale must be
stable

st.nld

**(7) ST.NLD=output after scale has
returned to zero range and is
stable. (OTHER>NLD.RG)

nld

**(8) NLD= Output after scale has
returned to zero range and does not
wait for the scale to be stable.
(OTHER>NLD.RG)

Pr.nLD

(9) PR.NLD= Manual push button
print once after scale is stable.
Scale has to return to zero range
(OTHER>NLD.RG) before another
push button print command can be
executed.

**Note: If PRINT, STABL, ST.NLD, LNLD or CMD are used to output data, the scale must be stable.