Salter Brecknell 6700U Series (USB) User Manual

Page 49

Advertising
background image

67XXU USB/Serial Scale Service Manual

49

HOLD

AD.H.SP

YES

NO

Enable or disable use of the
high speed A/D converter after
entering the HOLD mode

NO

HLD.MD

NONE

auto

Hold mode

(1) NONE= off

PS.PEK

(2) PS.PEK=Positive Peak number
Hold mode. Scale will display and
refresh the positive peak value from
last zero setting.

NG.PEK

(3) NG.PEK=Negative PEAK
number Hold mode. It is similar to
PS.PEK, but a negative number is
used.

TOGLE

(4) TOGLE=Press [HOLD] key to
enter HOLD mode. Stores the
display value. Will stay on the
display for the duration of time set
at HLD.TM.

AVERG

(5) AVERG= Average HOLD mode.
Time it looks at the weight before
updating the display. Set by
AVG.TM. Weight or vibration must
fall within window of HLD.RG also.

AUTO

(6) AUTO=Auto hold mode. It is
similar to AVERAG mode, but will
allow more weight to be added.

AVG.TM

1-60

3

Average data time for HOLD
mode

1-60 seconds

STB.TM 3XAVG.TIM

- 255

3X

AVG.TIM

Wait time for the scale to be
stable in HOLD mode

Window which has to be 3 times
larger than AVG.TM

HLD.TM

0-65535

0

Data HOLD time

0=data will be frozen until HOLD
key pressed.
1-65535=data frozen time is 1-
65535s, after the time elapses,
scale will exit HOLD mode.

HLD.RG

0-255

5

Hold range

Window of vibration for Auto to
work.
0=any data can be averaged
1-255= only the data which
vibration is in 1-255d can be
averaged and held.

hd.key

hold

hold

HOLD/PRINT key

(1) HOLD= only HOLD key

print

(2) PRINT= only PRINT key

hld.pr

(3) HLD.PR= HOLD and PRINT key

USER

SubMenu1 SubMenu2

Option

Default

Parameter Description

Comment

Advertising