Spare parts and accessories – Salter Brecknell 6115 User Manual
Page 28

Scale is not transmitting data to the host device
1. Check cable connection at both the rear of the
scale and the host device.
2. Check communication setting and baud rate
on both scale and software.
3. Perform I/O loopback test.
4. Replace the main board.
The ZERO key and the TEST key do not function
1. Open display enclosure and verify that the
keypad cable is still installed correctly.
2. Replace the display panel.
3. Replace the display PCB.
4. Replace the display cable.
5. Replace the main PCB.
DESCRIPTION PART NUMBER
Keyboard Panel
1163-14671
Display PCB LED
7405-15465
Display PCB Photo
7405-16860
Display Cable 20"*
1140-16912
Display Cable 2'
1140-14802
Display Cable 7'
1140-14217
Display Cable 14'
1140-14218
Load Cell (7.5 kg)
7154-16321-07
Load Cell (15 kg)
7154-16321-15
Main PCB Board
7405-16315
Power Supply 6103
1148-15535
Power Supply 6112/6115
1148-15536
RS-232 Cable
1140-13842
Magnetic Strip Kit
7200-17084
Feet 6103
7075-10256
Feet 6112/6115
7075-15144
Spare Parts and Accessories
25
*(used with rear flat bracket design)