Scale is not transmitting data to the host device
1. Check cable connection at both the rear of the

scale and the host device.

2. Check communication setting and baud rate

on both scale and software.

3. Perform I/O loopback test.
4. Replace the main board.

The ZERO key and the TEST key do not function
1. Open display enclosure and verify that the

keypad cable is still installed correctly.

2. Replace the display panel.
3. Replace the display PCB.
4. Replace the display cable.
5. Replace the main PCB.

DESCRIPTION PART NUMBER
Keyboard Panel

1163-14671

Display PCB LED

7405-15465

Display PCB Photo

7405-16860

Display Cable 20"*

1140-16912

Display Cable 2'

1140-14802

Display Cable 7'

1140-14217

Display Cable 14'

1140-14218

Load Cell (7.5 kg)

7154-16321-07

Load Cell (15 kg)

7154-16321-15

Main PCB Board

7405-16315

Power Supply 6103

1148-15535

Power Supply 6112/6115

1148-15536

RS-232 Cable

1140-13842

Magnetic Strip Kit

7200-17084

Feet 6103

7075-10256

Feet 6112/6115

7075-15144

Spare Parts and Accessories

25