Salter Brecknell 6115 User Manual
Page 5

Input:
120 VAC +10%, -15% Standard 3-wire
w/ground input
Optional: 230 VAC +10%, -15% Universal
adapter
Output:
15 VDC @ 0.3 Amps DC minimum
UL and CE approved
50/60 Hz
10-40º C
10% to 90% RH (non-condensing)
Stainless steel weigh platter
Aluminum base
Aluminum, single ended beam load cell
1/2" high 6-digit LCD in an extruded aluminum
enclosure
Tactile key panel with ZERO and TEST switches
Zero LED or Touchless Photoeye feature
Full positive or negative weight capacity
The 6103 has four feet located in each corner. The
6112 and 6115 have three feet with two located in
the front corners and one located in the middle
along the backside (tripod style). The feet are
secured in position and the scale normally does
not require leveling to operate properly.
The tripod design of the 6112 and 6115 feet place-
ment is unique as it provides for solid contact of
all three feet on most surfaces and makes foot
height adjustment unnecessary to stabilize the
scale. Caution must be followed to avoid place-
ment of heavy items directly on the rear corners,
which may cause tipping.
Power Supply
Line Frequency
Operating
Temperature
Construction
Display
Scale Feet
Tripod Design
2