Detex DTX-4300 User Manual

Page 15

Advertising
background image

Table 1-1. prox.pad plus Specifications

ELECTRICAL

Power Supply/Current
Requirements

10-15 VDC, linear filtered and regulated power supply
500 mA (not including locking device or peripherals)

WIRING

Remote Antenna Cable

ALPHA 1174C (22AWG) 4-wire, stranded (this is
required ONLY if you choose to remote the antenna
10 feet away from the keypad/controller)

RS-485 Cable

24AWG, shielded, two twisted-pair telephone cable
with a shunt capacitance of 16 pF/Ft (required only
when using software)

Power Supply Cable

18AWG - 22AWG 2-wire stranded (depends on
distance)

Door Lock Cable

18AWG - 22AWG 2-wire stranded (depends on
distance)

Door Monitor Cable

18AWG - 22AWG 2-wire stranded (depends on
distance)

REX Cable

(if using remote switch) 2-wire stranded

MECHANICAL

Height

5.25 in (13.3 cm)

Width

2.75 in (7 cm)

Depth

1.375 in (3.5 cm)

RELAY OUTPUTS

Main Relay - Form C (switches up to 2A)

Aux Relay - Form C (switches up to 2A)

MONITOR INPUTS

Door Position (Normally Closed, dry contact)

Request to Exit (REX, Normally Open, dry contact)

1.11 prox.pad plus Operation

Chapter 1: Introduction

prox.pad plus Install/Program. Manual, PPP, D4b

1-7

Part No. 6105679, Rev. 1.1

Advertising