To program users to a certain timezone, you must first
set the user timezone mask in command 32, parameter
5. Each user added after this parameter is set is as-
signed to that timezone. If you want to assign users to
several different timezones, you must change parame-
ter 5 prior to adding each user.

Take care using parameter 5 since it is an 8-bit number,
and each timezone equals a certain bit value as follows:

TZ1 = 1

TZ2 = 2

TZ3 = 4

TZ4 = 8

TZ5 = 16

TZ6 = 32

TZ7 = 64

TZ8 = 128

To program a user to multiple timezones, add up the
number of each timezone. For example: To add a user
to timezones 1, 2, and 8, enter 131 (1 + 2 + 128 = 131)
in parameter 5. Entering a value of 255 sets the user
to 24 hours, which means you cannot assign a user to
all eight (8) timezones. To set a timezone as auto-un-
lock, you must set the auto-unlock timezone mask
using command 38. Example:

38 # autz # 1 # **

(autz=auto-unlock timezone (1-8). Entering 1 sets the
timezone as auto-unlock and a 0 clears it.)

4.4.2.A Midnight Crossing TimeZones

The prox.pad plus unit supports “midnight crossing
timezones,” which is always enabled. This means a
timezone can cross the midnight boundary. For exam-
ple: A timezone can start at 11:00 P.M. and end at 7:00
A.M.

4.4 Programming Keypad Options and Parameters

Chapter 4: Programming

prox.pad plus Install/Program. Manual, PPP, D4b

4-23

Part No. 6105679, Rev. 1.1

Advertising