4.1.1 Programming
from the Keypad

The first step in programming the prox.pad plus unit
is to place it into Program mode. You can enter Program
mode with either the Master code or the Supervisor
code. When the prox.pad unit is in Program mode, the
yellow LED blinks slowly; when the yellow LED stops
blinking and is OFF completely, the unit is no longer
in Program mode. If an error is made in Program mode,
the yellow LED remains steadily lighted; press * to clear
the error condition and then re-enter the command. If
the unit does not go into Program mode, refer to the
Troubleshooting Chart in Chapter 5.

4.1.1.A Master Code (User Location #1)

The Master code is a special code stored in user location
one. This code is used to enter Program mode, and has
access to all programming commands.
To place the prox.pad plus unit in Program mode using
the Master code, press:

99 # Master Code *

NOTE:

“1234” is the default Master code, which IEI

recommends that you change right away.

To change the Master code, enter:

1 # new master code * new master code *
(example, 1 # 4321 * 4321 *)

NOTE:

Codes can be from 1 to 6 digits in length.

Chapter 4: Programming

4.1 Programming Overview

4-2

prox.pad plus Install/Program. Manual, PPP, D4b

Part No. 6105679, Rev. 1.1