4.2.2 Programming
User Types

Table 4-3 identifies and describes the user types sup-
ported by the prox.pad plus unit.

Table 4-3. prox.pad plus User Types

User Type

Numeric ID

Description

Toggle

0

Toggle users latch the lock in the unlock
position. Toggle mode is indicated by 6
quick beeps and a solid green LED.

Standard

1

Standard users use the lock duration
programmed in command 11.

Log Dump

2

For this user-type, the door remains locked
and the Transaction Log is dumped to the
DCD PDA software through the IR LED
when the appropriate code is entered. This
code cannot be used to gain access
through the door. The log is not erased,
only printed.

Lockout

3

Lockout users “lock out” other users - see
User Lockout (section 4.4.1). These codes
do not unlock the door.

Extended Unlock

4

Extended Unlock Users are like Standard
users except they use the unlock duration
programmed in command 32, parameter 3.
The default unlock time is 10 seconds.

Single Use Code

5

Single Use Codes are codes that can only
be used once. After the code is used, it is
deleted from the keypad. To verify a Single
Use is programmed, enter the sequence
[5# PIN *] and this looks up the PIN and
generates a 1/2 second green flash if the
PIN is programmed as a single use code. If
the PIN is not found, the system generates
three quick beeps and increments the
invalid PIN counter. If PIN is found but is
not programmed as a single use code, the
system does not respond at all.