Detex DTX-4300 User Manual

Page 56

Advertising
background image

When either the Master or Supervisor is pro-
grammed as “card AND code,” both are required
to enter Program mode.

When they are programmed for “card OR code,”
only the card is required to enter Program mode.

If the Master or Supervisor is programmed for
“card OR code” and you want them to require
both to enter Program mode, enable option 3 using
command 30 (30 # 3 # 1 # * *).

4.1.1.D prox.pad plus Default Settings

Table 4-1 lists the default settings for the prox.pad plus
unit as shipped from the factory. Subsequent sections
in this chapter explain how to change these default
settings or program additional functions.

Table 4-1. prox.pad plus Default Settings

Parameter

Default Setting

Main Relay

Lock Output

Auxiliary Relay

Alarm shunt function

Audio Alert #1

Forced Door

Audio Alert #2

Propped Door

Master Code (user one)

1234*

Main Relay energizes for

Five (5) seconds

Audible Keypress Feedback

ON

Propped Door Output activates after

Thirty (30) seconds

Forced Door Output activates for

Ten (10) seconds

Chapter 4: Programming

4.1 Programming Overview

4-4

prox.pad plus Install/Program. Manual, PPP, D4b

Part No. 6105679, Rev. 1.1