The prox.pad plus unit firmware can select one of four
different lockout operations. The selection is made by
setting the Lockout By Group “operand” in command
32, parameter 7 to one of the following values:

0 = lockout all other groups

1 = lockout just this group

2 = lockout higher numbered groups

3 = lockout lower numbered groups

When a “lockout just this group” is activated, all users
in that group are locked out with the exception of those
users programmed as Lockout Codes. This allows the
user who initiated the lockout to cancel the lockout.

4.4.2 TimeZone/
Holiday Features

The prox.pad plus unit currently supports up to eight
(8) timezones. Timezones are disabled by default and
can be enabled with Command 30 option 9. To enable,
enter:

30 # 9 # 1 # **

Auto-Unlock is also disabled by default and can be
enabled with command 30, option 11. The default
auto-unlock timezone is in location 8 and is 9:00 A.M.
to 5:00 P.M. Monday through Friday. To make this
timezone active as an auto-unlock, you must enable
option 11. To enable, enter:

30 # 11 # 1 # **

Additionally, you cannot add timezones through the
keypad directly (software is required); however, you
can assign users to timezones and set a timezone as
auto-unlock, after the timezone is added via software.