background image

2.4.2 Performing a
Glass Mounted
Installation

Figure 2-4 shows the four IEI-supplied pressure-sen-
sitive adhesive pads and the two side cut-outs used
for this installation. In this configuration, the prox.pad
plus unit is affixed with the four self-adhesive pads to
the glass or the glass window adjacent to the controlled
door being accessed, on the interior side of the glass.
One of the two side cut-outs is used to bring the wires
out of the side of the prox.pad plus case.

A typical glass mounted installation proceeds as fol-
lows:

1.

Disconnect the back housing from the front key-
pad/controller. Remove the tape from the four
self-adhesive pads on the back housing and apply
the pads to the four corners of the backplate.

2.

Affix the back housing to the glass door or the
glass window adjacent to the controlled door be-
ing accessed, on the interior side of the glass.

3.

Determine which of the two side cut-outs on the
back housing to use for the wiring and “cut out”
that cut-out using the appropriate cutting tool.

4.

Pull the wiring through the selected side cut-out
as required.

5.

Connect the front keypad/controller to the back
housing.

6.

Install the tamper screw into the hole at the bottom
front of the enclosure using a #6 spanner bit (not
included, but available from IEI).

2.4 Mounting the prox.pad plus Unit