Table 2-1. prox.pad plus Pin Connectors

Pin Connector (on
main circuit board)

Description/Use

P1 (5-pin connector, top
left-most location)

Pin

Wire Color

Use

1

GRAY

Main Relay, Normally
Closed (N.C.)

2

GREEN

Main Relay, Normally
Open (N.O.)

3

BLUE

Main Relay, Common

4

BLACK

Ground

5

RED

Power In, +12 VDC

P2 (6-pin connector, top
right-most location)

Pin

Wire Color

Use

1

GREEN

Aux Relay N.O.

2

GRAY

Aux Relay N.C.

3

BLUE

Aux Relay Common

4

BROWN

REX Loop (if used) (NO
contact)

5

ORANGE

Door Loop Contact (NC
contact)

6

WHITE

Loop Common (shared by
REX and door loop)

NOTE: Pins 1, 2, 3 can be wired at the installer’s option for
one of the following alarm outputs, Alarm Shunt, Forced
Door, or Propped Door. Mandatory: If you do not wish to
install door contacts per Figure 2-5, twist white and orange
wires together. If not done, REX input will not work.

P4 (4-pin connector,
bottom location)

Pin

Wire Color

Use

1

RED

Bi-Color LED (Red +)

2

BLACK

Bi-Color LED (Green +)

3

WHITE

Antenna (+)

4

WHITE

Antenna (-)

P-5 (4-pin connector,
left-hand side location)

Pin

Wire Color

Use

1

Blue

Terminator

2

Brown

Data A

3

White

Data B

4

Green

Data GND

2.3 Checking the Cables