Detex DTX-4300 User Manual

Page 68

Advertising
background image

4.2.6 Block Delete of
Users

Command 58 lets you delete a block of users. To lessen
the chance of accidental deletion, the command se-
quence requires a double entry of the starting user and
number of users values. If the values entered do not
match, a programming error occurs. The format of the
new command is as follows:

58 # start user # start user # number of
users * number of users *

The yellow led blinks rapidly during the deletion proc-
ess; it can take several seconds to delete all 2000 users.

4.2.7 Deleting Users

To delete a user from the prox.pad plus unit’s memory,
you must know the user location in which the infor-
mation is stored. Printing a Programmed Users List (as
described in section 4.5) helps you determine this, if
you are using the DCD software. If not, the program-
mer should have filled out a paper chart listing the
memory location or register in which all users are
stored.

To delete a user, follow the steps below.

1.

Place the prox.pad plus unit in Program mode.
Press :

99 # Master Code * (default is 1234)

A slow blinking yellow LED indicates that the unit
is in Program mode. A steady yellow LED, in
contrast, means that errors were detected during
programming. Error states can be cleared by press-
ing the asterisk * key.

2.

On the prox.pad plus keypad, enter the user
location

you wish to delete and a pound symbol

#. To delete user 100, for example, press:

100 # ** (to delete user 100)

The yellow LED blinks slowly.

3.

Press * to exit Program mode.

Chapter 4: Programming

4.2 Programming Users

4-16

prox.pad plus Install/Program. Manual, PPP, D4b

Part No. 6105679, Rev. 1.1

Advertising