1.

Place the prox.pad plus unit in Program mode.
Press:

99 # Master Code * (default is 1234)

A slow blinking yellow LED indicates that the unit
is in Program mode. A steady yellow LED, in
contrast, means that errors were detected during
programming. Error states can be cleared by press-
ing the asterisk * key.

2.

To enable this feature, press:

30 # 1 # 1 # **

The yellow LED continues to blink slowly.

3.

To disable this feature, press:

30 # 1 # 0 # **

The yellow LED continues to blink slowly.

4.

Press * to exit Program mode.

4.4.4 Turning Audio
Keypress Feedback
ON/OFF

The Audio Keypress Feedback command enables the
sounder to beep once for each key press. This feature
provides an audio acknowledgment that a particular
key was pressed hard enough for the unit to under-
stand. The factory-shipped default setting is ON, but
it can be toggled ON and OFF as desired using com-
mand 30. NOTE: A common reason to turn this feature
OFF is to prevent an unauthorized user from hearing
the audio feedback emitted when an authorized user
enters his/her code.
1.

Place the prox.pad plus unit in Program mode.
Press:

99 # Master Code * (default is 1234)

A slow blinking yellow LED indicates that the unit
is in Program mode. A steady yellow LED, in
contrast, means that errors were detected during
programming. Error states can be cleared by press-
ing the asterisk * key.

2.

To enable this feature, press:

30 # 0 # 1 # **

Chapter 4: Programming

4.4 Programming Keypad Options and Parameters

4-26