Detex DTX-4300 User Manual

Page 57

Advertising
background image

Table 4-2. prox.pad plus LED Indicators/Sounder Operations

LED or Sounder

Visual/Audible
Condition

Description

Yellow LED

Slow blink

Unit is in Program mode

Rapid blink

Verify mode is active (checking that the
last two values in sequence match)

Steady

Program error; to clear, press * or error
lockout

Very rapid blink

Memory (eeprom) erase is in progress
(commands 40/46, loop-back)

Bi-color LED

Steady red

Lock output deenergized

Steady green

Lock output is energized (timed or
latched)

Red/green
alternating

Awaiting second PIN during “Card AND
Code” access attempt

Green blink

Auto-unlock active

Sounder

Short beep
(100 ms) every 2
seconds

Audio alert #2 is active

Sounder 1/2 sec
on, 1/2 sec off

Audio alert #1 is active

Double beep

Lockout is canceled

Pair of double
beeps

Lockout is activated

3 slow beeps
(250 ms), then
single beep

Self-test is complete

4.1 Programming Overview

Chapter 4: Programming

prox.pad plus Install/Program. Manual, PPP, D4b

4-5

Part No. 6105679, Rev. 1.1

Advertising