9. Password Reuse Count The number of password expirations a user must wait until a

password can be reused. When set to 0, the user can reuse their current password with
no count limitation. When set to 1, a password can be reused after one password reset.

3.4.2 Lockout/Logout Configuration

Select the Lockout/Logout Configuration item you want to change by typing the corresponding
number. Press Enter to close the editing function and then press Esc to return to the System
Configuration menu.

10. Lockout After Failed Attempts The number of attempts a user may make before the

account becomes disabled. The Lockout Type field controls the lockout behaviors. Enter
a value between 1 and 15. A setting of 0 will disable this feature.

11. Lockout Type The options are Hard or Timed. Timed requires the user to wait a

specified number of minutes before a retry. Hard requires the System Administrator to
unlock the account. Press the Space bar to select Timed or Hard.

Lockout Time

The number of minutes that a user must wait before a retry. Enter a value

between 0 and 30.

12. Display Lockout Message Specifies if a message will be displayed when an account

has been locked. Refer to the Lockout Message in option 13. Press the Space bar to
select Enabled or Disabled.

13. Lockout Message The text to be displayed if option 12 is Enabled. The message should

be customized to list the person to contact in case an account is disabled. Enter a text
message of up to 30 characters.

14. Lockout Craft Port Specifies whether the RS-232 serial port interface on the device

should be locked to prevent using the serial interface to access the system. Press the
Space bar to select Enabled or Disabled.

15. Inactivity Logout Time The number of minutes of inactivity before a user is

automatically logged out. Enter a value between 1 and 30. A setting of 0 will disable this
feature.