CANOGA PERKINS 9145E NID Software Version 3.1 User Manual

Page 155

Advertising
background image

9145E NID Software User’s Manual

Service OAM

Maintenance Associations

140

d. Press Esc to return to the Maintenance Associations Attributes screen.

NOTE: When you select a MEP ID while creating a maintenance end point

from a peer MEPs list (Figure 11-16), the selected MEP ID becomes
local to the device and the rest of the MEP IDs automatically become
peers. You must define MEP IDs in a given MA prior to creating MEP
in the 9145E.

5. You can change the Permissions (Sender ID). Select None, Chassis, Manage, ChassisManage, or

Defer, and press Enter.

6. When you are finished, type A to accept the settings and press Enter.

7. Press Esc to return to the Maintenance Association List screen.

Figure 11-15 Maintenance Association Attributes screen

Canoga Perkins Corp. Ethernet Network Interface Device 02-JAN-2009
9145E-101-1-0 V03.10(GA0014) 00:25:46
----------------------MAINTENANCE ASSOCIATION ATTRIBUTES-----------------------

MD ID: 2 Level: 0
MA ID: 2 Name: port-layer

1) CCM Interval: 1 sec

VLAN Tag Type: S-Tag
VLAN List: 100

2) Add VLAN to VLAN List.
3) Remove VLAN from VLAN List.

4) View/Modify Peer MEPs list.
5) Permissions (Sender ID): None

Select [1-5] for attributes: